Turbidity & suspended solids instrumentation, historically based in Port Townsend, WA Product line now supported through Campbell Scientific, Inc.
A bold yellow angular logo mark set against a deep dark background, sharp and modern
D & A Instruments
Turbidity monitors & water-quality instrumentation

Blog

  1. Designing Suspended-Solids Feedback for Dredge ControlAutomatic dredging systems increasingly use optical measurements to control production rate, pump output, cutter speed, overflow behaviour, or vessel movement.…
  2. Managing Air Interference in Optical Solids MonitoringOptical suspended-solids instruments are widely used in wastewater treatment because they provide rapid, continuous information without the delay of laboratory…
  3. Verification of Turbidity Sensor Linearity Using Dual Standard Dilution SeriesA turbidity sensor is often described as linear when its output rises in proportion to the concentration of suspended material. In practice, that assumption…
  4. Choosing Optical Sensor Housings for Extreme Water ChemistryOptical instruments used in dredging, hydrology, environmental research and industrial monitoring can encounter water far outside the neutral range. Acid…
  5. Using groundwater profilers to map saltwater intrusionSaltwater intrusion occurs when seawater or naturally saline groundwater moves into a freshwater aquifer. The process is common in coastal areas where…
  6. Monitoring Sediment Resuspension During Dredge OperationMaintenance dredging keeps navigation channels open for container ships, bulk carriers, ferries and workboats, yet the excavation process can disturb fine…
  7. Managing Power for Long-Duration Optical Sediment MonitoringLong-duration optical sediment monitoring depends on a simple engineering truth: a sensor can collect excellent data only while the complete field system has…
  8. Deploying Turbidity Sensors in Pipes and ConduitsIndustrial effluent rarely behaves like a calm stream in an open channel. It moves through pressurised pipes, gravity conduits, pumping stations, sumps and…
  9. Minimum Detection Limits of Common Turbidity Sensors ComparedA turbidity sensor’s minimum detection limit is the lowest change in water clarity that it can distinguish reliably from electronic noise, optical interference…
  10. Optical Backscatter Sensors for Glacial Meltwater Sediment FluxGlacial meltwater carries a changing mixture of clay, silt, sand and organic material from ice, moraine and exposed rock. During warm periods or intense…